10kv and 35kv Aerial Insulated Power Cable

Model NO.: JS-007
Wire Core Material: Aluminum
Certification: ISO, CCC, CE
Model: AGRP
Brand: Jinshui
Trademark: JINSHUI
Transport Package: Drum
Specification: 1.1*1.1*1.1
Origin: Zhengzhou Henan
HS Code: 4107961636
Model NO.: JS-007
Wire Core Material: Aluminum
Certification: ISO, CCC, CE
Model: AGRP
Brand: Jinshui
Trademark: JINSHUI
Transport Package: Drum
Specification: 1.1*1.1*1.1
Origin: Zhengzhou Henan
HS Code: 4107961636
Aerial Insulated Power Cable up to 10kV and 35kV
  1. Standards and Scope of Application
The products adopt IEC ,NFC ,and so on , and they are suitable for aerial distribution electrical lines with rated AC voltage U(Um)10(12) Kv and 35(42) kv
  1. Specific Property for Using
  1. The min . temperature of laying cable is not lower than -20 C.
  2. The max . temperature of HDPE insulated cable is 150 C , and that of the XLPE insulated cable is 250 C during short circuit (less than 5 seconds)
  3. The max . long-time working temperature of the HDPE insulation is 75 C and that of the XLPE insulated cable is 90 C .
  4. Every fault time of single-phase earthing shall be less than one minute .And that also shall be less than 8 hours per time and be less than 125 hours every year .
  5. The permissible curving radius of single-core cable should be not less than 20(D+d)+ 5%mm , and that of the milti-core cable should be not less than 15(D+d)+5%mm .10kv and 35kv Aerial Insulated Power Cable
    10kv and 35kv Aerial Insulated Power Cable
    10kv and 35kv Aerial Insulated Power Cable
Aerial Insulated Power Cable up to 10kV and 35kV
  1. Standards and Scope of Application
The products adopt IEC ,NFC ,and so on , and they are suitable for aerial distribution electrical lines with rated AC voltage U(Um)10(12) Kv and 35(42) kv
  1. Specific Property for Using
  1. The min . temperature of laying cable is not lower than -20 C.
  2. The max . temperature of HDPE insulated cable is 150 C , and that of the XLPE insulated cable is 250 C during short circuit (less than 5 seconds)
  3. The max . long-time working temperature of the HDPE insulation is 75 C and that of the XLPE insulated cable is 90 C .
  4. Every fault time of single-phase earthing shall be less than one minute .And that also shall be less than 8 hours per time and be less than 125 hours every year .
  5. The permissible curving radius of single-core cable should be not less than 20(D+d)+ 5%mm , and that of the milti-core cable should be not less than 15(D+d)+5%mm .10kv and 35kv Aerial Insulated Power Cable
    10kv and 35kv Aerial Insulated Power Cable
    10kv and 35kv Aerial Insulated Power Cable

Standard Recovery Stud Diode

Standard Recovery Stud Diode are mainly used for rectifying and switching


It has positive pressure reduction (0.4v -- 1.0v), short reverse recovery time (2-10ns nanosecond), large reverse leakage current, low pressure resistance, generally lower than 150V, and is used in low voltage situations.

Diodes are electronic devices that have two electrodes that allow only a single current to flow in a single direction.Varicap bond (bond) is an electronic adjustable capacitor.Most diodes have a current orientation that we call reading "rectifier".The most common function of a diode is to allow only the current to pass in one direction (called forward bias) and to block in the opposite direction (called reverse bias).




Standard Recovery Stud Diode,Standard Recovery Diode,400V Standard Recovery Diode,Stud Diode

YANGZHOU POSITIONING TECH CO., LTD. , https://www.cnfudatech.com