The front panel of the ST consists of a liquid crystal display and 16 buttons that display two lines per line and can display 16 characters. DC Capacitor For Electric Furnace DC Capacitor for Electric Furnace DC Capacitor For Electric Furnace,DCMJ DC Filter Capacitors,DCMJ Pulse Capacitors,DCMJ DC Support Capacitors YANGZHOU POSITIONING TECH CO., LTD , https://www.yzpstcc.com
The 16 buttons of the ST are divided into two parts:
4 vertical on the left:
MODULE returns to the main menu of the service tool anywhere in the service tool software.
FUNCTION returns to the installation and service function menu for selection at any point in the system
SET returns to the project menu at any position in the function. The blue button for selecting the installation and maintenance function is equivalent to the upper key SHIFT on the computer keyboard. (The white part of the button is not pressed when the blue button is pressed, and the button blue is pressed after pressing the blue button. Color part function) When you press the blue button, you will see a blinking cursor appear in the first character position of the ST display. This means that the blue key function is valid. When you press the corresponding function key, this flashing The cursor will disappear.
The twelve buttons on the right are all composed of half white, half and blue. When you press normally, the white part is used. If you want to use the blue part, you need to press the unmarked symbol in the lower left corner of the keyboard. The blue button is then pressed the function key you want to press. The function of the blue button and the twelve buttons on the right is the same as that on the computer keyboard. The blue button is equivalent to the upper key SHIFT on the computer keyboard.
FUNCTION key function
SHIFT + 4 hexadecimal number A
SHIFT + 5 hexadecimal number B
SHIFT + 6 changes the sign or hexadecimal number C of any number that has been entered
SHIFT + 7 hexadecimal number D
SHIFT + 8 hexadecimal number E
SHIFT + 9 hexadecimal number F
CLEAR erases the last digits entered (if there is an error)
SHIFT + CLEAR (this function is equivalent to the ENTER Enter key in the computer keyboard) to save or save the value after saving
GO ON forward conversion display
GO BACK Converts the display backwards (press the SHIFT button first, then when the GO ON/GO BACK button is pressed, the GO BACK function will be implemented.
ST uses:
After inserting the ST into the interface of the Otis elevator board, the ST display will first display: SELF TEST – OK- MECS-MODE, which means: ST self-test passes, the current connection is the modular elevator control system mode. This display is normal. If other words appear, please unplug the ST and re-insert it in the experiment. If the problem cannot be solved, it may be that the ST or the elevator component has failed.